Services / EV chargers, panel upgrades, generators and batteries

Electrification permit package

One-line diagram, load calculation, site plan, labels and the filled permit form for EV chargers, service and panel upgrades, standby generators and home batteries. Pick one item or bundle several on the same job.

For: Electricians, EV charger installers, generator dealers, solar and battery installers. US, Canada, Australia and UK.

What you get

  • Cover sheet with scope, code edition and general notes
  • Site plan with equipment locations, meter, panel and run route
  • Single-line diagram with conductor, conduit, OCPD and grounding sizes
  • Load calculation (NEC 220.82/220.83, CEC 8-200, AS/NZS 3000 Appendix C or BS 7671 diversity, by country)
  • Equipment schedule and spec sheets
  • Required labels and placards
  • Filled permit application, ready to sign

Usually within 2 business days of getting everything we need. Rush is available. One round of changes from the permit office or utility is included.

Price

Electrification package (first item)NEEDS BRIAN'S PRICE
Each extra item on the same job
e.g. EV charger plus panel upgrade
NEEDS BRIAN'S PRICE
Rush, add-onNEEDS BRIAN'S PRICE

Permit, utility and engineer fees are not included. If your job needs an engineer's stamp, we confirm the cost and timing before we start.

What we'll ask for

  • What is being installed?
  • Electric utility
  • Service voltage
  • Existing service / main breaker (A)
  • Existing main panel make and model
  • Conditioned floor area (sq ft or m², say which)
  • Major existing loads (range, dryer, A/C or heat pump, water heater, hot tub, other EVs)
  • Main heating type

The order form only asks the questions that apply to your job.

What to upload

  • Utility meter (number readable)
  • Main panel label (bus and main breaker rating)
  • Main panel with the cover off (breakers visible)
  • Where the new equipment will go

Helpful if you have them:

  • Rough site sketch with the run route (photo of a sketch is fine)
  • Spec sheets for the new equipment

Drawn to your local rules

We draw to the code edition your permit office uses and look up its local requirements first.

United States

NEC load calculation (220.82/220.83/220.87), Article 625 EV charging, 230 services, 702 standby generators, 706 energy storage with IRC R328 / NFPA 855 battery locations.

Canada

Canadian Electrical Code Rule 8-200 load calculation, Section 86 EV charging, EV energy management (8-106), Section 64 energy storage, provincial amendments.

Australia

AS/NZS 3000 maximum demand, AS/NZS 3010 generators, AS/NZS 5139 batteries, your state's Service and Installation Rules and DNSP paperwork.

United Kingdom

BS 7671 maximum demand and Section 722 EV charging, Section 551 generators, battery guidance (IET Code of Practice, PAS 63100), DNO notification.

Questions

Can you avoid a service upgrade?

Often. We run the load calculation first. If the numbers are close, an energy management or load management device can let the EV charger fit on the existing service where your code and AHJ allow it.

Several things on one job?

Yes. Tick everything being installed (for example an EV charger plus a panel upgrade) and it goes in one package with one load calculation.